Start-up Time, Run-up Time, and R9 Analysis for ENERGY STAR Lamps - PowerPoint PPT Presentation

Start-up Time, Run-up Time, and R9 Analysis for ENERGY STAR Lamps V2.0 Draft 1 Section 11.4: Start Time Start up Time for Lamps meeting V1.1 Efficacy Requirements by Lamp Category 5,147 1,873 2,764 510 100% 4,963 1,834 2,663 466 1,710 90%


  1. Start-up Time, Run-up Time, and R9 Analysis for ENERGY STAR Lamps V2.0 Draft 1

  2. Section 11.4: Start Time Start ‐ up Time for Lamps meeting V1.1 Efficacy Requirements – by Lamp Category 5,147 1,873 2,764 510 100% 4,963 1,834 2,663 466 1,710 90% 4,430 2,293 427 80% Percent of Products Meeting Level 1,371 70% 60% 268 2,656 50% 99% 99% 99% 100% 97% 96% 95% 91% 91% 85% 84% 82% 40% 1,017 73% 30% 52% 51% 20% 36% 10% 0% 100 250 500 750 Milliseconds All Omnidirectional Directional Decorative • Data pulled from QPL on 3/5/15 • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power

  3. Section 11.4: Start Time Start ‐ up Time for Lamps meeting V2.0 Proposed Efficacy Requirements – by Lamp Category 2,428 630 1,574 224 623 100% 2,324 1,507 553 90% 194 Percent of Products Meeting Level 1,975 1,254 80% 168 70% 60% 297 50% 99% 100% 99% 100% 99% 95% 95% 88% 87 86% 903 40% 81% 79% 75% 519 30% 47% 20% 39% 37% 33% 10% 0% 100 250 500 750 Milliseconds All Omnidirectional Directional Decorative • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power. – 95% of lamps that meet the proposed efficacy levels have a start time of 500 milliseconds or less.

  4. Section 11.4: Start Time Start ‐ up Time for Lamps meeting V1.1 Efficacy Requirements ‐ by Technology 5,147 1,364 3,783 100% 4,963 1,343 1,335 1,304 3,620 90% 4,430 3,095 Percent of Products Meeting Level 80% 70% 60% 2,656 50% 99% 99% 99% 97% 97% 96% 95% 95% 85% 40% 81% 1,352 30% 51% 20% 35% 10% 0% 100 250 500 750 Milliseconds All CFL LED • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power

  5. Section 11.4: Start Time Start ‐ up time for Lamps meeting V2.0 Proposed Efficacy Requirements – by Technology 2,428 106 2,322 100% 2,324 100 2,224 99 98 90% Percent of Products Meeting Level 1,975 1,876 80% 70% 60% 50% 99% 99% 99% 95% 95% 93% 93% 92% 903 40% 81% 80% 805 30% 20% 37% 34% 10% 0% 100 250 500 750 Milliseconds All CFL LED • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power. – 95% of lamps that meet the proposed efficacy levels have a start time of 500 milliseconds or less.

  6. Section 11.5: CFL Run-Up Time Run ‐ up Time for CFL Lamps Meeting V1.1 Efficacy Requirements – by Lamp Category 1,103 100% 1,084 1,267 979 90% Percent of Products Meeting Levels 1,144 80% 1,006 90 70% 74 60% 535 50% 99% 97% 92% 550 88% 83% 40% 41 73% 66% 63% 30% 48% 20% 40% 35% 16 19 11 6 9 10% 14% 14% 7% 5% 8% 0% 30 45 60 90 Seconds All Omnidirectional Directional Decorative • V1.1: Covered CFLs must achieve 80% stabilized light output in ≤ 120 seconds and all other CFLs must achieve 80% stabilized light output in ≤ 60 seconds • Proposed V2.0: Lamp must achieve 80% stabilized light output in ≤ 60 seconds

  7. Section 11.5: CFL Run-Up Time Run ‐ Up Time for CFL Lamps Meeting V2.0 Efficacy Requirements – by Lamp Category 103 104 104 105 100% 96 97 90% Percent of Products Meeting Levels 80% 70% 60% 57 57 50% 100% 99% 98% 97% 92% 91% 40% 1 1 1 30% 55% 53% 20% 33% 33% 33% 0 0 0 0 0 10% 0% 0% 0% 0% 0% 0% 30 45 60 90 Seconds All Omnidirectional Directional Decorative • V1.1: Covered CFLs must achieve 80% stabilized light output in ≤ 120 seconds and all other CFLs must achieve 80% stabilized light output in ≤ 60 seconds • Proposed V2.0: Lamp must achieve 80% stabilized light output in ≤ 60 seconds. – 97% of lamps that meet the proposed efficacy levels have a run-up time of 60 seconds or less.

  8. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V1.1 Efficacy Requirements – by Lamp Category 100% 1,213 4,322 2,686 423 90% 80% 70% Percent of Products 64% 60% 83% 83% 96% R9>0 50% R9<=0 40% 30% 20% 36% 674 10% 17% 17% 865 88 103 4% 0% All Omnidirectional Directional Decorative • V1.1: No R 9 requirement for CFLs • Proposed V2.0 requirement of R 9 >0

  9. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V2.0 Efficacy Requirements – by Lamp Category 100% 571 223 2,383 1,589 90% 80% 70% Percent of Products 60% 90% 97% R9>0 50% 100% 99% R9<=0 40% 30% 20% 10% 1 63 60 2 10% 3% 0% 0% 1% All Omnidirectional Directional Decorative • V1.1: No R 9 requirement for CFLs • Proposed V2.0 requirement of R 9 >0 – 97% of lamps that meet the proposed efficacy requirements have R 9 >0

  10. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V1.1 Efficacy Requirements – by Technology 100% 4,322 3,808 514 90% 37% 80% 70% Percent of Products 60% 83% R9>0 50% 100% R9<=0 40% 864 63% 30% 20% 10% 17% 865 1 0% 0% All CFL LED • V1.1: No R 9 requirement for CFLs • Proposed V2.0 requirement of R 9 >0

  11. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V2.0 Efficacy Requirements – by Technology 100% 2,383 45 2,338 90% 80% 42% 70% Percent of Products 60% 97% R9>0 50% 100% R9<=0 40% 30% 58% 20% 10% 1 63 62 3% 0% 0% All CFL LED • Proposed V2.0 requirement of R 9 >0 • Currently, 82% of lamps on the ENERGY STAR Certified Lamps Product List have an R 9 >0 – 97% of lamps that meet the proposed efficacy requirements have R 9 >0