nova experiment status all experimenter s meeting
play

NOvA Experiment Status All Experimenters Meeting Jaroslav Zalesak, - PowerPoint PPT Presentation

NOvA Experiment Status All Experimenters Meeting Jaroslav Zalesak, FNAL/Institute of Physics, Prague Jun 6, 2016 Op Operation ons s Su Summary q BEAM: Waiting for 700kW with 6+6 slip stacking and antineutrino run. q NearDet: No


  1. NOvA Experiment Status All Experimenter’s Meeting Jaroslav Zalesak, FNAL/Institute of Physics, Prague Jun 6, 2016

  2. Op Operation ons s – Su Summary q BEAM: — Waiting for 700kW with 6+6 slip stacking and antineutrino run. q NearDet: — No issues during last 2 weeks. — Preparing for the maintenance and planning of noise lowering to make the RHC data taking as much effective as possible. q FarDet: — A water leak! — Short timing issue (glitch in TDU). — Thunder storm season ongoing, a power glitch occurred. q Collaboration: week @ Argonne, asked for box opening for the Second analysis results, preparing for summer conferences. — Discussion about beam summer shutdown tasks. 2 Jaroslav Zalesak - NOvA Phone Meeting 6/6/16

  3. FD: : Water L Leak Ø Forgotten brass fitting (on APD water hose) caused the water leak May 27 at 8pm. Ø 7.5 h down time to isolate, search and unplugged damaged electronics parts, Ø And of course recovery the detector. Ø Down times for replicating (12 FEBs + 2 APDs) and take new DSO scans and HV settings. 3 Jaroslav Zalesak -AEM 6/6/16

  4. FD: : Data t taking U Uptime Power glitch WATER LEAK TDU/TCR Repairs of Timing issue damaged No beam parts Maintenance Ø 92.4%, 98.8% (4w 96.9%) Ø The main issue was the water leak Fri/Sat and its recovery. Ø Other down times for replacing damaged parts, we were 6h with one diblock excluded. Ø And the thunder storm season caused one short power glitch on Sun. 4 Jaroslav Zalesak -AEM 6/6/16

  5. FD: : POTs d delivered/recorded 93.2 % 100% 100 % 99.2 % Ø 4week average 97.9%, last weeks we took 13.22 of 13.33 and 13.56 of 14.55 e18 POTs. Ø Since second analysis cut-off we took 60+e18 POTs more. Ø Big beam losses correspond to the water leak and power glitch at Ash River site. 5 Jaroslav Zalesak -AEM 6/6/16

  6. FD: : Accumulated POTs – al all year ars Ø FY2014: 280/326 e18 POTs (86%) + FY2015: 298.5/312.5 *) e18 POTs (95.5%) [253days] Ø FY2016: 346.2/359.2 e18 POTs (96.1%) [210 days] *) Including 20.8e18 POTs horn-off data and 2.6e18 non-nominal horn current data. Ø Total beam exposure of FD reached 0.998 e21 POTs (not weighted). 6 Jaroslav Zalesak -AEM 6/6/16

Recommend


More recommend