Cooling Operation 030 Model Ambient Indoor DB / 21/15 27/19 - PDF document

Cooling Operation 030 Model Ambient Indoor DB / 21/15 27/19 32/23 Temp Outdoor WB 18 35 43 2 2 2 Quantity Indoor PC Quantity in Operation 2 2 2 Unit Condition Model - 015 020 015 020 015 020 5 5 5 Main Pipe


  1. Cooling Operation 030 Model Ambient Indoor DB / 21/15 27/19 32/23 Temp Outdoor WB 18 35 43 2 2 2 Quantity Indoor PC Quantity in Operation 2 2 2 Unit Condition Model - 015 020 015 020 015 020 5 5 5 Main Pipe Piping Branch Pipe m 5 5 5 22 22 22 Total Piping Length Refrigerant Volume 2.6 2.6 2.6 kg Outdoor Total Current A 13.0 20.0 21.0 Unit Volts 220 220 220 V EXV Indoor Unit 150 150 250 250 400 400 STEP Opening S.C (EXV4) 0 0 0 High Pressure 11.5 19 25 Pressure Bar Low Pressure 4.1 4.2 5.2 Discharge (TH1) 60.0 95.0 98.0 Outdoor 10.0 15.0 15.0 Suction (TH12) Unit Compressor Bottom 45.0 60.0 65.0 Temp °C Coil In (Ti) 5.0 9.0 16.0 Indoor 5.5 9.5 16.5 Coil Mid (Tm) Unit Coil Out (To) 7.5 10.5 17.5

  2. Cooling Operation 040 Model Ambient Indoor DB / 21/15 27/19 32/23 Temp Outdoor WB 18 35 43 4 4 4 Quantity Indoor PC Quantity in Operation 4 4 4 Unit Condition Model - 010 010 010 010 010 010 010 010 010 010 010 010 5 5 5 Main Pipe Piping Branch Pipe m 5 5 5 22 22 22 Total Piping Length Refrigerant Volume 4.7 4.7 4.7 kg Outdoor Total Current A 12.5 19.0 20.5 Unit Volts 220 220 220 V EXV Indoor Unit 150 150 150 150 250 250 250 250 400 400 400 400 STEP Opening S.C (EXV4) 0 0 0 High Pressure 11.0 17.5 23.0 Pressure Bar Low Pressure 4.8 5.0 6.5 Discharge (TH1) 65.0 85.0 97.0 Outdoor 12.0 17.0 25.0 Suction (TH12) Unit Compressor Bottom 55.0 85.0 75.0 Temp °C Coil In (Ti) 5.0 9.0 16.0 Indoor 5.5 9.5 16.5 Coil Mid (Tm) Unit Coil Out (To) 7.5 10.5 17.5

  3. Cooling Operation 050 Model Ambient Indoor DB / 21/15 27/19 32/23 Temp Outdoor WB 18 35 43 2 2 2 Quantity Indoor PC Quantity in Operation 2 2 2 Unit Condition Model - 025 025 025 025 025 025 5 5 5 Main Pipe Piping Branch Pipe m 5 5 5 22 22 22 Total Piping Length Refrigerant Volume 4.7 / 4.9 4.7 / 4.9 4.7 / 4.9 kg Outdoor Total Current A 13.0 / 5.5 24.5 / 8.5 26.0 / 9.5 Unit Volts 220 / 380 220 / 380 220 / 380 V EXV Indoor Unit 150 150 250 250 350 350 STEP Opening S.C (EXV4) 0 0 0 High Pressure 11.0 18.0 24.0 Pressure Bar Low Pressure 4.6 4.9 6.5 Discharge (TH1) 70.0 90.0 100.0 Outdoor 12.0 15.0 20.0 Suction (TH12) Unit Compressor Bottom 45.0 55.0 65.0 Temp °C Coil In (Ti) 5.0 9.0 16.0 Indoor 5.5 9.5 16.5 Coil Mid (Tm) Unit Coil Out (To) 7.5 10.5 17.5

  4. Cooling Operation 060 Model Ambient Indoor DB / 21/15 27/19 32/23 Temp Outdoor WB 18 35 43 2 2 2 Quantity Indoor PC Quantity in Operation 2 2 2 Unit Condition Model - 020 040 020 040 020 040 5 5 5 Main Pipe Piping Branch Pipe m 5 5 5 22 22 22 Total Piping Length Refrigerant Volume 5.0 5.0 5.0 kg Outdoor Total Current A 7.5 11.0 12.0 Unit Volts 380 380 380 V EXV Indoor Unit 150 150 250 250 300 300 STEP Opening S.C (EXV4) 0 0 0 High Pressure 10.5 18.0 24.0 Pressure Bar Low Pressure 4.4 4.6 6.2 Discharge (TH1) 65.0 90.0 98.0 Outdoor 10.0 12.0 18.0 Suction (TH12) Unit Compressor Bottom 45.0 55.0 70.0 Temp °C Coil In (Ti) 5.0 9.0 16.0 Indoor 5.5 9.5 16.5 Coil Mid (Tm) Unit Coil Out (To) 7.5 10.5 17.5

  5. Cooling Operation 070 Model Ambient Indoor DB / 21/15 27/19 32/23 Temp Outdoor WB 18 35 43 4 4 4 Quantity Indoor PC Quantity in Operation 4 4 4 Unit Condition Model - 015 015 020 020 015 015 020 020 015 015 020 020 5 5 5 Main Pipe Piping Branch Pipe m 5 5 5 22 22 22 Total Piping Length Refrigerant Volume 5.5 5.5 5.5 kg Outdoor Total Current A 9.5 11.5 14.0 Unit Volts 380 380 380 V EXV Indoor Unit 150 150 150 150 250 250 250 250 400 400 350 350 STEP Opening S.C (EXV4) 0 0 0 High Pressure 16.0 18.5 25.0 Pressure Bar Low Pressure 4.2 5.0 6.0 Discharge (TH1) 74.0 90.0 98.0 Outdoor 12.0 16.0 16.0 Suction (TH12) Unit Compressor Bottom 40.0 55.0 65.0 Temp °C Coil In (Ti) 6.5 10.0 15.5 Indoor 7.0 10.0 16.0 Coil Mid (Tm) Unit Coil Out (To) 7.5 10.5 17.5

  6. Heating Operation 030 Model Ambient Indoor DB / 20/15 20/19 27/19 Temp Outdoor WB -9 7/6 21/15 2 2 2 Quantity PC Indoor Quantity in Operation 2 2 2 Unit Condition Model - 015 020 015 020 015 020 5 5 5 Main Pipe Piping m 5 5 5 Branch Pipe Total Piping Length 22 22 22 Refrigerant Volume 2.6 2.6 2.6 kg Outdoor Total Current 13.0 20.0 21.0 A Unit Volts V 220 220 220 EXV Indoor Unit 450 400 450 400 450 400 STEP Opening EXV 1 150 300 350 High Pressure 13.5 16.5 16.7 Pressure Bar Low Pressure 1.5 3.0 5.5 Discharge (TH1) 80.0 85.0 82.0 Outdoor Suction (TH12) -17.0 3.0 14.6 Unit 40.0 50.0 65.0 Compressor Bottom Temp °C Coil In (Ti) 34.0 40.0 40.0 Indoor 35.5 45.0 45.0 Coil Mid (Tm) Unit 65.0 75.0 75.0 Coil Out (To)

  7. Heating Operation 040 Model 20/15 20/16 27/19 Ambient Indoor DB / Temp Outdoor WB -9 7/6 21/15 4 4 4 Quantity PC Indoor Quantity in Operation 4 4 4 Unit Condition Model - 010 010 010 010 010 010 010 010 010 010 010 010 5 5 5 Main Pipe Piping m 5 5 5 Branch Pipe Total Piping Length 22 22 22 Refrigerant Volume 4.7 4.7 4.7 kg Outdoor Total Current 15.0 16.5 12.5 A Unit Volts V 220 220 220 EXV Indoor Unit 450 450 450 450 450 450 450 450 450 450 450 450 STEP Opening EXV 1 170 250 200 High Pressure 11.5 14.0 14.0 Pressure Bar Low Pressure 1.8 3.4 5.5 Discharge (TH1) 50.0 70.0 75.0 Outdoor Suction (TH12) -16.3 4.0 17.0 Unit 21.5 42.0 54.0 Compressor Bottom Temp °C Coil In (Ti) 28.0 34.0 38.0 Indoor 30.0 38.0 40.0 Coil Mid (Tm) Unit 50.0 65.0 70.0 Coil Out (To)

  8. Heating Operation 050 Model Ambient Indoor DB / 20/15 20/15 27/19 Temp Outdoor WB -9 7/6 21/15 2 2 2 Quantity PC Indoor Quantity in Operation 2 2 2 Unit Condition Model - 025 025 025 025 025 025 5 5 5 Main Pipe Piping m 5 5 5 Branch Pipe Total Piping Length 22 22 22 Refrigerant Volume 4.7 / 4.9 4.7 / 4.9 4.7 / 4.9 kg Outdoor Total Current 18.0 / 6.5 20.5 / 7.5 18.0 / 6.5 A Unit Volts V 220 / 380 220 / 380 220 / 380 EXV Indoor Unit 400 400 400 400 400 400 STEP Opening EXV 1 150 250 200 High Pressure 12.0 14.7 15.0 Pressure Bar Low Pressure 1.8 3.5 5.3 Discharge (TH1) 80.0 80.0 85.0 Outdoor Suction (TH12) -10.0 4.0 12.0 Unit 12.0 35.0 45.0 Compressor Bottom Temp °C Coil In (Ti) 31.0 36.0 39.0 Indoor 32.0 39.0 41.0 Coil Mid (Tm) Unit 60.0 70.0 72.0 Coil Out (To)

  9. Heating Operation 060 Model Ambient DB / 21/15 21/15 27/23 Indoor Temp Outdoor WB -9 7/6 21/15 2 2 2 Quantity Indoor PC Quantity in Operation 2 2 2 Unit Condition Model - 020 040 020 040 020 040 Main Pipe 5 5 5 Piping m 5 5 5 Branch Pipe 22 22 22 Total Piping Length Refrigerant Volume kg 5.0 5.0 5.0 Outdoor Total Current 7.5 8.5 9.5 A Unit Volts 380 380 380 V EXV Indoor Unit 400 400 400 400 400 400 STEP Opening EXV 1 150 250 250 High Pressure 12.5 16.5 16.0 Pressure Bar Low Pressure 1.8 3.4 5.8 58.0 80.0 83.0 Discharge (TH1) Outdoor Suction (TH12) -14.0 4.0 15.0 Unit Compressor Bottom 10.0 40.0 55.0 Temp °C 28.0 36.0 39.0 Coil In (Ti) Indoor Coil Mid (Tm) 30.0 39.0 41.0 Unit 52.0 70.0 72.0 Coil Out (To)

  10. Heating Operation 070 Model Ambient Indoor DB / 20/15 20/15 27/19 Temp Outdoor WB -9 7/6 21/15 4 4 4 Quantity PC Indoor Quantity in Operation 4 4 4 Unit Condition Model - 015 015 020 020 015 015 020 020 015 015 020 020 5 5 5 Main Pipe Piping m 5 5 5 Branch Pipe Total Piping Length 22 22 22 Refrigerant Volume 5.5 5.5 5.5 kg Outdoor Total Current 9.5 10.5 12.5 A Unit Volts V 380 380 380 EXV Indoor Unit 450 450 400 400 450 450 400 400 450 450 400 400 STEP Opening EXV 1 150 250 258 High Pressure 12.1 15.5 19.7 Pressure Bar Low Pressure 1.8 3.4 6.6 Discharge (TH1) 75.0 85.0 95.0 Outdoor Suction (TH12) -14.0 6.0 13.0 Unit 20.0 40.0 53.0 Compressor Bottom Temp °C Coil In (Ti) 24.0 39.0 40.0 Indoor 25.5 42.0 50.0 Coil Mid (Tm) Unit 58.0 70.0 85.0 Coil Out (To)