waterfront substation
play

Waterfront Substation October 29, 2015 Project Update I Pepco - PowerPoint PPT Presentation

Waterfront Substation October 29, 2015 Project Update I Pepco Holdinqs Inc 2 ~ ~ Waterfront Substation Project Phase Progress Phase 1: Regulatory authorization and zoning BZA approval received in March 2015 and DC PSC approval


  1. Waterfront Substation October 29, 2015

  2. Project Update I Pepco Holdinqs Inc 2

  3. ~ ~ Waterfront Substation • Project Phase Progress • Phase 1: Regulatory authorization and zoning • BZA approval received in March 2015 and DC PSC approval in April 2015 QStSW • Phase 2: Substation site preparation Waterfront • Substation Environmental assessment finished and demolition will complete in early November 2015 nc W; d Impacted • Phase 3: Design & construction of the substation, St<eets transmission and distribution lines • Detail engineering and permitting is underway • Distribution construction beginning Nov 2015 S St SW ..... • Transmission construction beginning Dec 2015 ..... VI Buzzard Pt - • Substation construction beginning Jan 2016 "' . Substation .. G-, l- ) "O C N I Pepco Holdings Inc 3

  4. Waterfront Substation Project Schedule June – November 2015 Prepare Waterfront Site for Construction July 2015 – July 2016 Award EPC Contract; Perform Detail Engineering Obtain Building Permit January 2016 January 2016 – April 2017 Construct Substation Building August 2016 – April 2017 Install Electrical Equipment May 2017 – June 2017 Initial Transfer of Electrical Load I Pepco Holdinqs Inc 4

  5. Demolition Update I Pepco Holdinqs Inc 5

  6. Demolition Update • Pepco contractor Northstar performed demolition of existing Lyon Bakery and ANA towing office buildings • Demolition phase is nearing completion I Pepco Holdings Inc 6

  7. Demolition – Measures & Controls • Water spraying mounted hose and nozzles for dust suppression • Continuous humidity/moisture content in the construction debris • Prevention of dust from becoming airborne • Portable water tanks cover smaller blanket of airborne dust areas without blowing any water or dust laden mist outside the property limits Construction vehicles cleaned prior to departing construction site I Pepco Holdings Inc 7

  8. Demolition – Vector Control & Abatement • Northstar placed ten bait stations around the perimeter of the site prior to demolition • Department of Health bureau of community hygiene and rodent control division inspected the site on July 28th 2015 and issued clearance certification • The contractor also hired Critter Control (Rodent Control company) as secondary measures • Bait stations inspections reveal no evidence of rodents • Northstar has requested follow up DOH site inspection post demolition 8 Pepco Holdings nc

  9. Demolition – Site Controls • Installation of Stabilized Construction Entrance, silt fence and super silt fence as part of the Erosion and Sediment control measures • Construction debris and Asbestos containing building material segregated, covered and hauled off site for disposal I Pepco Holdings Inc 9

  10. Substation Engineering & Construction Update I Pepco Holdinqs Inc 10

  11. Waterfront Substation Construction January 2016 - April 2017 • 60% detail design complete • Pepco will install up to 20,000 sf of PV Panels on the roof of the substation for station service I Pepco Holdings Inc 11

  12. About ABB USA ABB USA is a world leader in power • technology ABB is working with Pepco to enhance • Pepco’s transmission network in Washington DC – improving reliability and efficiency with this advanced substation I Pepco Holdings Inc 12

  13. About Coakley & Williams Construction, Inc. Founded in 1961 CREBA Recently Ranked Us Best Contractor Award Winning Technology Services Sustainable Construction 215 Industry Awards Strong, Local Relationships 2 13

  14. About Coakley & Williams Construction, Inc. 2 14

  15. ~ Waterfront Substation Landscape i t:i (J) 0 z N PEPCO WATERFRONT SUBSTATION #223 I Pepco Holdings Inc 15

  16. Waterfront Substation Landscape APPROX APPROX - LOCATION LOCATIOt~ OFPOW£R SlR((T Of POWCR u~u mr UN(S IIMNO) "-NCilt CAOltUGttr 11· s· .J Jl'.!,'' -r- •. -+- 6' lRSTP.Ul.SW In STRUT.SW f)I (l(C llM ()C rl[C.UNf 1• 1'' • 1" II' l ' ' ' ' ' PLA~T!NG AIIEA Sl()(WAI.IC TREE 8IOR(TE,,,.10N ' \ ,. ..•. P\ANllt.G a·, .. 10Nr Ul"4WArtP.LINt. ()( l"WATEl\llNl U. 4' GAS I.IN( (ABNO I (X 1\"SI.NIT,U't'UNf tlt!UC UN( lX-EUtLINE , STREETSCAPE SECTIO N · 1ST STREET , SW - SOU TH STREETSCAPE SEC TI ON - 1ST STREET , SW - MIOBLOCK 2 0 1" 00 , 1,lfl·. 1 ·.o· 014001 118"• t',O" .,. .. APPROX APPAO)( --. l,OCAllON LOCATION or POWER STRUT 0,POW(R TR(( UNO LINtS (BEVONOt SI..C.(E Gl06C LIGHT S[CURfT'Y FENC( lM" JJ' f," PLANTING NOOk SJOl WAUC s· .. - ,. .. •· - I I.MSJIIIHT , SW QSTRUI SW ,, DIST MANtlOLF (SU \ ' \ ' ' \ UT1ll1" OAAWINGS) '"5Tflll5U110N LINt rx . a~wAm~w..ir lX. I" WAftfl LINE I.SU UTIUfY PlAAS) CONCIIICT!' oucr flANl(S fl'YPJ (X, 21" $A.~n'AA'f llNt CONCR[T( l)UCT BAN• cm ()( IS~SANITAAYUkE. j5£[ UllllTYPIANS) E< 4" QA$ LINE (A81t01 VTIIJTV.._.N~) £)( . 2•" SANlf.U.Y UN! ST REETSCAPE SECTIO N · 1ST STREET , SW · NO R TH • STREETSCAPE SEC TI ON · 0 STREE T, SW · o· 0 1<• 001 119· • 1 0t4 001 1 ,r • 1'• O" I Pepco Holdings Inc 16

  17. ~,~ J~ ~ Waterfront Substation Landscape """"°' lOCATIOff Slll([T - ()fl'()W(O TR(£ UNU IIICYONOI ft.OYo"ER~ 111tr TI!H IBffl>NDI ,OU'DNDI - ~ - 8' -+- 6' - .. lndSTREET,SW 1ndSTRE.ET S.W fX CO¥M.l1Nl ... ' ' _.;r ' ' ' U.2.I4Y-.hJTAATural: ut 2l"SNtl1AA¥U,.,_t. P,1.V1~ EX t2•SAJrcfTAAVU,ME EX Jl"'S,,tJt1T4RYU~E cx.rwAtutUNr cx.a•wATLllUNI ' •J• SANllu." UNC 0. ot CZ'"SAkrTNIT IJ..HE - lAANSMrWDNllNCS. £X EUCTlllCU"-£ U ELKTRICLNE 1su unurr PIAN~ STREETSCAPE SECTION· 2ND STREET, SW· NORTH STREETSCAPE SECTION· 2ND STREET. SW· SOUTH OMOQZ 118 ' • 1'·0" 01 4 0Q2 111"'•1'·0 ' I ~~~'~'?°''" c-~ [I ! m,o, """'°' APPfK>)I, I lOCAnON ~ ! UXATION or POwfA orPQWc11 ..... """ UNB llN[S ..... ' ii i • MCDIUMS'TIIEIT I I MfM,IM l~H ltlfVOND) 'ff"-rn Sl"KiUGLOM 811ClllACK rLOW(rtlNG I ~;:;- "'" T"1£ UGHT t8CVONOt (IE'f'ONDI .... n• ,~ ,s·r 14' 4,.,.ux, IIAl'ito ·· - .. PlANTlll - 9'·.J~ 10 - 10 ---:,. M T] PR[{AST SIO[WAL( 110.C P.:,U~rrr. SW [)( [LCC.UN( U111UT.1W CX (t£C,U.N( lllitkm ,!. w (X.[l{C.L,H( PloV(llS ""'' .. ' -• ' " 24'1' I ' I , \'AULl PR[CA!.TPA'/[RS TR[( TIW,SMISSIC>N Ui;fS TIIANSMoSSIONLINfS [lC.Jt•~ITAII.VUN( EX. ll"SAN lASc V UN[ Cx. ll"SAM'TMV UN[ iSHU'f11WfPI.AN1) tll J"C,ASLIN( (\H UIH,H\' PLAN$ ~ IX 1"0.UUN~ ltl'G.ASI.IN( I ,. --1 I rMHs~,s~HUNf. C!.E£Ulllll'fPV.Nli) , STREETSC A PE SECT I ON· R STREET , SW · WEST , STREETSC AP E SECT ION • R STREET , SW · WEST • STREETSCAPE SECT I ON • R ST REET , SW • EAST 01•00:l ,..-. 1 ·.o· 0 14 001 111' • 1 '·0" 0 14 002 , •••• 1'·0" I Pepco Holdings Inc 17

  18. Waterfront Substation Landscape Plant Palette I Pepco Holdings Inc 18

  19. Transmission Engineering & Construction Update I Pepco Holdinqs Inc 19

  20. Overall Underground Transmission and Distribution  Map on slide 20 was removed • Underground Transmission (Under Construction) from the original presentation • Underground Transmission Lines Phase 1 for publication on website • Underground Transmission Lines Phase 2 • Future Ductbank on New Bridge • Underground Distribution Lines I Pepco Holdings Inc 20

  21. Underground Transmission Lines  Map on slide 21 was removed from 138kV Underground Lines the original presentation for between Buzzard Point publication on website Substation and Waterfront Substation. Construction: December 2015  March 2017 Ductbank for future Underground Transmission Feeders Construction: March 2016  July 2017 I Pepco Holdinqs Inc 21

  22. Underground Transmission Installation Video www.pepco.com/Underground-Construction.aspx I Pepco Holdinqs Inc 22

  23. Distribution Engineering & Construction Update I Pepco Holdinqs Inc 23

  24. Distribution Conduit Phase 1: November 2015 - April 2016  Map on slide 24 was removed from the original presentation for publication on website I Pepco Holdinqs Inc 24

  25. Traffic Control ·- - ~ 25

  26. Potential Yard Disturbance  Map on slide 26 was removed from the original presentation for publication on website I Pepco Holdings Inc 26

  27. Distribution Conduit Phase 2: 2017 and beyond  Map on slide 27 was removed from the original presentation for publication on website I Pepco Holdinqs Inc 27

  28. Questions I Pepco Holdinqs Inc 28

  29. Appendix I Pepco Holdinqs Inc 29

Recommend