summary sc quantum detectors 2 hr 45m 3 hr 30m
play

Summary : SC/Quantum detectors 2 hr 45m 3 hr 30m two long days - PowerPoint PPT Presentation

Summary : SC/Quantum detectors 2 hr 45m 3 hr 30m two long days with detectors for astronomy, dark matter and neutrinos and photo-detectors in genera: TES,SNSPDs, MKIDs J.Estrada (fnal) Transition Edge Sensors for CMB going BIG!


  1. “Summary” : SC/Quantum detectors 2 hr 45m 3 hr 30m two long days with detectors for astronomy, dark matter and neutrinos… and photo-detectors in genera: TES,SNSPDs, MKIDs J.Estrada (fnal)

  2. Transition Edge Sensors for CMB going BIG! T.Cecil

  3. TES in direct DM : going low! N.Kurinsky large R&D effort exploring several options, impressive progress HVeV v2: Combining Lessons

  4. K. Karkare : Line Intensity Mapping (with MKIDs)

  5. deployment in January 2020 MKIDs spectrograph on a chip! E. Shirokoff

  6. MKIDs for optical and near IR improving resolution B. Mazin 20k channels of spectroscopy with R~10… at telescope also for axion/dark photon

  7. J. Ouellet G. Cancelo quantum devices (TWPA) to improve the electronics needed for these performance of these highly multiplexed highly multiplexed arrays of systems MKIDs and TES

  8. A. Drilica-Wagner non destructive readout with skipper-CCD could enhanced cosmological observations

  9. M. Shaw started us on SNSPDs Parameter SOA 2019 SOA 2016 Group Efficiency 98% @ 1550 nm 93% @ 1550 NIST Dark Counts < 1e-5 cps < 0.1 cps MIT Energy 0.125 eV 0.250 eV NIST/JPL/MIT Threshold Timing Jitter 2.7 ps 16 ps MIT/JPL/NIST Active Area 0.92 mm 2 0.058 mm 2 NIST Max Count Rate 1.2 Gcps 0.3 Gcps JPL Pixel Count 1024 (32x32) 64 (8x8) NIST/JPL Photon Number 1 from 2 or more None MIT Operating Temp 4.3 K @ 1550 2.5 K @ Single Quantum snspd

  10. perhaps these guys are having too much fun…

  11. J.Chiles SNSPD+haloscope large detectors low dark current!

  12. I.Charaev the SNPD detectors for haloscope (impressive dark count rate!)

  13. T.Polakovic SNSPDs in strong magnetic field Developed a new technique for the fabrication of films that can operate in very high field.

  14. V.Verma astronomy in the plans

  15. W. Chung speeding up axion search SC cavity could allow df high B, in mixed state − 2 dt ∼ B 4 V 2 C 2 Q L T syst ! YBCO tape cavity prototype tested

  16. Josephson Photomultiplier (JPM) R.McDermott High-fidelity counter-based QB measurement Science 361, 1239 (2018)

  17. A. Dixit: qubits for single photon detection in Axion search.

  18. Doug Pinckney : HeRALD

  19. Y.J.Kim dark matter search with atomic magnetometers recently published constraints

Recommend


More recommend