www.elvac.eu SCADA MikroDispečink News Vlastimil Janik
Mikrodispečink Control system for electric stations and dispatching centers Editing Module - WEdit It is now possible for users to edit description of signal states, signal attributes and measures and also some other texts visible in the Journal and few other screens. In the past those were hardcoded in the modules. Dispatcher areas names have been moved into configuration file WMD.INI. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Editing Module - WEdit Added copy and move functionality for config tables of same type. Data moving functionality can also automatically update depenent tables icluding objects in graphics schemes, e.g.: remote control and conversion table of IEC104 communication system. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Editing Module - WEdit Searching for ANY text in a scheme. The same functionality is also available in the viewer. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Editing Module - WEdit New features in manual export of samples: Export using one second period. • Export can contain number of changes the values. • It is possible to choose data separator (quotation mark, semicolon). • Templates for list of exported values. • www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Editing Module - WEdit New units added: kW and W. New types of graphical objects in schemes are now available: Two Windings Transformator (secondary side, same voltage level). • Reactor. • Winding. • Number of items in signal type database (PopSig) were increased to 5000. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Main User Module - Viewer Open scheme with a signal that caused record insertion into the journal. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Main User Module - Viewer Refresh of schema coloring depending on connection (topology). It is also possible to select coloring area like the one that is controlled by a dispatcher. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Main User Module - Viewer Printing of composite diary is now available also in dispatcher workstation mode. Export of diary into csv or xls file format => enables it is further processing in external tools. Export of normal states deviations into csv or xls file. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers New Features and Possibilities New function Register of Unavailibilities supports an evidence of devices that are not functioning in production due to technical issues. It is not only possible to add and cancel such events, but also showing them in schemas and lists of outages. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers New Features and Possibilities Create new signal based on a value of measurement limit value. Useful e.g. for signalisation of voltage in schemas of viewer modules. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers New Features and Possibilities Join signal or measurement database with other same type databases . Might help solving various system issues. Useful in the viewer module when browsing list of objects or list of elements. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers New Features and Possibilities Business measurement module now also support export into daily text file. It is now possible to export data not only into external databases, but also into text file in „csv” format. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers New Features and Possibilities Sheets subsystem: Number of sheeted values 4000. • Sheated values list size between 50 and 100. • Maximal number of sampled values was increasd to 170 000. User login subsystem was enhanced in the viewer module Menu actuialization. • It is not possible to login with other than default user. • Option for selection of a directory with translation files. Loader module design has been enhanced ☺ . www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Communication Module – KOMX, KOMX61850, Elvac communicator Support for new communication modules in MKD: KOMX for communication via protocol IEC61850. • ELVAC communicator testing for communication directly into MKD without using • classic KOMX module. Change of structure of configuration table for routes, even if new communication modules are not used. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Communication Modules – KOMX Strategy change in communication system via IEC104 protocol – definition split into down direction (into substation) and into upper direction (SCADA system). www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Communication modules – KOMX Change measured value (it’s decimal point – multiply or divide by powers of ten) at the MKD’s input for values that are fed into the MKD system by IEC104 communication protocol. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Communication Module – KOMX Increased number of possible communication endpoints: For protocol IEC104 to 30000 rows. • For protocol IEC101 to 10000 rows. • Communication of IEC101 supports negated signalization and measurement of MKD input. Change of „Window size” parameter’s range for IEC104 communication. IEC104 communication can now add a point without outage. www.elvac.eu Own Products
Mikrodispečink Control system for electric stations and dispatching centers Future plans Deployment of redundant installation of MKD into production in energetics enterprises. Move ELVAC communicator IEC104 module from testing into production phase. Implement new web client with all functions of common viewer to meet current technological standards. Implement installer (setup) for simple MKD system (substation+dispatching). Meet other needs of our customers. www.elvac.eu Own Products
O Společnosti Thank you for your attention Hasičská 53, Tel.: +420 597 407 100 700 30 Ostrava - Hrabůvka E-mail: sales@elvac.eu Czech Republic www.elvac.eu, www.rtu.cz www.elvac.eu
Recommend