01 18 2019 jmk offices www hdg architecture com spokane
play

01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA - PowerPoint PPT Presentation

EXISTING BUMP OUT AND SIDEWALK TO REMAIN MAIN PROPOSED NEW CURB IN EXISTING CURB REQUIRED NEW STREET ON STREET PARKING LOCATION TREES 20'-0" PARKING PARKING STALL TYP. MIN. 9'-0" 6 SIDEWALK 12'-0" MIN. NEW SIDEWALK


  1. EXISTING BUMP OUT AND SIDEWALK TO REMAIN MAIN PROPOSED NEW CURB IN EXISTING CURB REQUIRED NEW STREET ON STREET PARKING LOCATION TREES 20'-0" PARKING PARKING STALL TYP. MIN. 9'-0" 6 SIDEWALK 12'-0" MIN. NEW SIDEWALK NEW SIDEWALK 25'-0" MAX NEW LANDSCAPE NEW LANDSCAPE MAIN ENTRY DOOR AND NEW "SIDEWALK CAFE" 8'-6" SIDELIGHT 3'-4" ENTRY ENTRY ENTRY CLR TYP. DN DN ENTRY JMK OFFICES PINE 30'-0" POTENTIAL COFFEE TENANT DN +/- 540 S.F. "LOBBY" DN DN TYP. 5'-0" RAMP 1:12 WAITING SLOPE MAX ENTRY BUILT-IN WAITING BENCH POTENTIAL RESTAURANT TENANT +/- 775 S.F. PATIO DN 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  2. DN UP EXISTING WALL 2.1 WALL TYPE 1. UNLESS NOTED OTHERWISE ALL INTERIOR DIMENSIONS ARE TAKEN FROM FACE NEW STUD WALL OF STUD FOR NEW WALLS. AND FACE OF FINISH FROM EXISTING WALLS 2. DIMENSIONS INDICATING "CLEAR" OR F.O.W. ARE TAKEN FROM FINISH. INTERIOR ELEVATION TAG 1/A1.1 3. COORDINATE ALL WALL/CEILING PENETRATIONS WITH GENERAL CONTRACTOR. PARTITION/FURRING DOOR SYMBOL 4. COORDINATE ALL MECHANICAL EQUIPMENT WITH GENERAL CONTRACTOR. # 5. COORDINATE ALL LIGHTING CONTROL PLACEMENT WITH DESIGNER. PARTITION W/ SOUND BATT. 6. VERIFY/COORDINATE DIMMING SYSTEMS WITH DESIGNER. INSULATION B WINDOW SYMBOL 7. PROVIDE SIGN ON BOTH EXIT DOOR TO READ: "THIS DOOR TO REMAIN UNLOCKED WHILE SPACE IS OCCUPIED" MASONRY WALL 8. LIQUOR BOARD/HEALTH DEPARTMENT REQUIRED SIGNAGE BY OWNER VNL FLOOR TRANSITION 9. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND PROPOSED DESIGN AND F.O.W. FACE OF WALL (FINISH) CPT CONSTRUCTION VIA A SITE VISIT/WALK THROUGH WITH THE ARCHITECT. 10. FINDINGS AND ANY DIRECTIVES ARISING FROM ANY VISIBLE AND ACCESSIBLE AREAS OF THE EXISTING CONDITION FROM THE THE AFOREMENTIONED VERIFICATION MEETING WILL BE IN CABINET FEC CONSIDERED PART OF THE BID AND CONSTRUCTION DOCUMENTS. 2A-10BC FIRE 11. COORDINATE ALL WALL/CEILING/ ROOF PENETRATIONS WITH GENERAL CONTRACTOR. EXTINGUISHER 12. COORDINATE ALL MECHANICAL EQUIPMENT WITH GENERAL CONTRACTOR. F.E. 13. COORDINATE ALL LIGHTING CONTROL PLACEMENT WITH ARCHITECT. WALL HUNG 14. VERIFY/COORDINATE DIMMING SYSTEMS WITH ARCHITECT. 15. VERIFY WITH OWNER ALL POWER.DATA REQUIREMENTS AND LOCATIONS. 16. PROVIDE A RBPA AT ALL POP MACHINES, ICE MAKERS, COFFEE MAKERS, ETC. 17. KNOX BOX BRAND KEY BOX, 3200 SERIES, WITH KEYS TO THE BUILDING. ORDER THE KNOX BOX LINE @ KNOXBOX.COM. THE ORDER MAY TAKE UP TO TWO WEEKS FOR DELIVERY. MOUNT AT A HEIGHT BETWEEN 5-6 FEET ABOVE FINISHED GRADE 18. ADDRESS NUMBERS TO BE 4" HIGH WITH 1/2" STROKE WIDTH MIN. AND CONTRAST WITH THEIR 1. PARTITION TYPES ARE GENERIC PARTITION CONSTRUCTION. SEE FINISH BACKGROUND. NUMBERS TO BE ARABIC OR ALPHABETIC LETTERS SCHEDULE TO IDENTIFY SPECIFIC MATERIALS TO BE USED FOR THE 19. ALL WALLS EXTEND TO STRUCTURE ABOVE U.N.O SUBSTRATE. THIS MUST BE USED TO UNDERSTAND THE ENTIRE ASSEMBLY 20. PER SECTION 1008.1.9 OF THE 2012 IBC: AND ITS FINISHES. EGRESS DOORS SHALL BE READILY OPENABLE FROM EGRESS SIDE WITHOUT THE USE OF A KEY 2. PROVIDE WATER RESISTANT GYP BD IN ALL WET AREAS. OR SPECIAL KNOWLEDGE OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR 3. ALL WALLS ARE W4.1 UNLESS OTHERWISE NOTES. TWISTING OF THE WRIST TO OPERATE. 4. "H" REPRESENTS A PARTIAL HEIGHT WALL 21. SEE SHEET A1.1 SITE PLAN FOR EXTERIOR SEATING. 22. ALL NEW INTERIOR DOORS TO BE HOLLOW METAL. STUD TYPE AND SIZE 23. ALL DOOR HARDWARE TO BE SATIN NICKEL FINISH AND COMPLY WITH ADA ACCESSIBILITY REQUIREMENTS. WALL TYPE 24. COORDINATE LOCKING DEVICES/TYPES WITH OWNER. 25. COORDINATE ALL CASEWORK WITH OWNER PROCURED INTERIOR DESIGNER. 26. VERIFY ALL SEATING LAYOUTS WITH OWNER PROCURED INTERIOR DESIGNER. 27. VERIFY ALL DIMENSIONS WITH EQUIPMENT REQUIRED CLEARANCES. 28. EXISTING MECHANICAL TO REMAIN. W4.0 29. ADJUST DUCTS BY MECHANICAL CONTRACTOR. W4.1 - 2X4 WOOD STUD AT 16" O.C. WITH ONE LAYER OF 5/8" GYP BOARD ON EACH SIDE. 01.18.2019 W4.2 JMK Offices W4.3 www.hdg-architecture.com W6.1 Spokane, WA W6.2 509.321.5064 W6.3 M6.1

  3. EXISTING WALL 2.1 WALL TYPE 1. UNLESS NOTED OTHERWISE ALL INTERIOR DIMENSIONS ARE TAKEN FROM FACE NEW STUD WALL OF STUD FOR NEW WALLS. AND FACE OF FINISH FROM EXISTING WALLS 2. DIMENSIONS INDICATING "CLEAR" OR F.O.W. ARE TAKEN FROM FINISH. INTERIOR ELEVATION TAG 1/A1.1 3. COORDINATE ALL WALL/CEILING PENETRATIONS WITH GENERAL CONTRACTOR. PARTITION/FURRING DOOR SYMBOL 4. COORDINATE ALL MECHANICAL EQUIPMENT WITH GENERAL CONTRACTOR. # 5. COORDINATE ALL LIGHTING CONTROL PLACEMENT WITH DESIGNER. PARTITION W/ SOUND BATT. 6. VERIFY/COORDINATE DIMMING SYSTEMS WITH DESIGNER. INSULATION WINDOW SYMBOL B 7. PROVIDE SIGN ON BOTH EXIT DOOR TO READ: "THIS DOOR TO REMAIN UNLOCKED WHILE SPACE IS OCCUPIED" MASONRY WALL 8. LIQUOR BOARD/HEALTH DEPARTMENT REQUIRED SIGNAGE BY OWNER VNL FLOOR TRANSITION 9. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND PROPOSED DESIGN AND F.O.W. FACE OF WALL (FINISH) CPT CONSTRUCTION VIA A SITE VISIT/WALK THROUGH WITH THE ARCHITECT. 10. FINDINGS AND ANY DIRECTIVES ARISING FROM ANY VISIBLE AND ACCESSIBLE AREAS OF THE EXISTING CONDITION FROM THE THE AFOREMENTIONED VERIFICATION MEETING WILL BE IN CABINET FEC CONSIDERED PART OF THE BID AND CONSTRUCTION DOCUMENTS. 2A-10BC FIRE 11. COORDINATE ALL WALL/CEILING/ ROOF PENETRATIONS WITH GENERAL CONTRACTOR. EXTINGUISHER 12. COORDINATE ALL MECHANICAL EQUIPMENT WITH GENERAL CONTRACTOR. F.E. WALL HUNG 13. COORDINATE ALL LIGHTING CONTROL PLACEMENT WITH ARCHITECT. 14. VERIFY/COORDINATE DIMMING SYSTEMS WITH ARCHITECT. 15. VERIFY WITH OWNER ALL POWER.DATA REQUIREMENTS AND LOCATIONS. 16. PROVIDE A RBPA AT ALL POP MACHINES, ICE MAKERS, COFFEE MAKERS, ETC. 17. KNOX BOX BRAND KEY BOX, 3200 SERIES, WITH KEYS TO THE BUILDING. ORDER THE KNOX BOX O LINE @ KNOXBOX.COM. THE ORDER MAY TAKE UP TO TWO WEEKS FOR DELIVERY. MOUNT AT A HEIGHT BETWEEN 5-6 FEET ABOVE FINISHED GRADE 18. ADDRESS NUMBERS TO BE 4" HIGH WITH 1/2" STROKE WIDTH MIN. AND CONTRAST WITH THEIR 1. PARTITION TYPES ARE GENERIC PARTITION CONSTRUCTION. SEE FINISH BACKGROUND. NUMBERS TO BE ARABIC OR ALPHABETIC LETTERS SCHEDULE TO IDENTIFY SPECIFIC MATERIALS TO BE USED FOR THE 19. ALL WALLS EXTEND TO STRUCTURE ABOVE U.N.O SUBSTRATE. THIS MUST BE USED TO UNDERSTAND THE ENTIRE ASSEMBLY 20. PER SECTION 1008.1.9 OF THE 2012 IBC: AND ITS FINISHES. EGRESS DOORS SHALL BE READILY OPENABLE FROM EGRESS SIDE WITHOUT THE USE OF A KEY 2. PROVIDE WATER RESISTANT GYP BD IN ALL WET AREAS. OR SPECIAL KNOWLEDGE OR EFFORT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR 3. ALL WALLS ARE W4.1 UNLESS OTHERWISE NOTES. TWISTING OF THE WRIST TO OPERATE. 4. "H" REPRESENTS A PARTIAL HEIGHT WALL 21. SEE SHEET A1.1 SITE PLAN FOR EXTERIOR SEATING. 22. ALL NEW INTERIOR DOORS TO BE HOLLOW METAL. STUD TYPE AND SIZE 23. ALL DOOR HARDWARE TO BE SATIN NICKEL FINISH AND COMPLY WITH ADA ACCESSIBILITY REQUIREMENTS. WALL TYPE 24. COORDINATE LOCKING DEVICES/TYPES WITH OWNER. 25. COORDINATE ALL CASEWORK WITH OWNER PROCURED INTERIOR DESIGNER. 26. VERIFY ALL SEATING LAYOUTS WITH OWNER PROCURED INTERIOR DESIGNER. 27. VERIFY ALL DIMENSIONS WITH EQUIPMENT REQUIRED CLEARANCES. 28. EXISTING MECHANICAL TO REMAIN. W4.0 29. ADJUST DUCTS BY MECHANICAL CONTRACTOR. W4.1 01.18.2019 JMK Offices W4.2 www.hdg-architecture.com W4.3 Spokane, WA W6.1 509.321.5064 W6.2 W6.3 M6.1

  4. 3 1 VIBES 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  5. Black Infjniti Laminate High Refmective White 7757 Tricorn Black 6258 White Infjniti Laminate Shaw City Central Tile - Skyline Porcelanosa - Aged Dark Natural Oak Laminate Padua - Light Natural Silestone - Iconic Black United Tile - Loop Night Black Padua - Dark Natural Evoke - Hunter Au Naturel 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  6. White Infjniti Laminate Polished Concrete High Refmective White 7757 CB2 - Capitol Black Bell 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  7. Black Infjniti Laminate Natural Oak Laminate Polished Concrete CB2 - Capitol Black Bell Luminance - Black Wall Sconce RH - Soho Black Tufted Sofa 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  8. Polished Concrete White Infjniti Laminate Black Infjniti Laminate Natural Oak Laminate Porcelanosa - Aged Dark 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  9. Polished Concrete Black Infjniti Laminate Natural Oak Laminate Porcelanosa - Aged Dark Black Plastic Eames Chair 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  10. High Refmective White 7757 Illuminate Vintage - Sconce United Tile - Loop Night Black Fab Glass Mirror 799456351780 Padua - Light Natural Padua - Dark Natural 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

  11. High Refmective White 7757 Padua - Light Natural United Tile - Loop Night Black Silk Plants - Phalaenopsis Orchid Padua - Dark Natural 01.18.2019 JMK Offices www.hdg-architecture.com Spokane, WA 509.321.5064

Recommend


More recommend