ISOVER MULTICOMFORT HOUSE STUDENTS CONTEST EDITION 2018 DRAFTERS: VEIS ALINA MECHSHANOVA NURIYA CONSULTANT: YASKEVICH VLADIMIR KAZAKHSTAN/ SATBAYEV UNIVERSITY
INSPIRATION
CONCEPT
GENERAL VIEW
MASTER PLAN
FLOOR PLAN AT THE LEVEL -5600 - Locker room - Parking - Pedestrian way - Recreation pavilion - Shop - Place for car - Boat rental - Mechanic area
GENERAL VIEW
GENERAL VIEW
FLOOR PLAN AT THE LEVEL +4500 Short-term type of residence Long-term type of residence Permanent type of residence
FLOOR PLAN AT THE LEVEL +4500 One-room apartment Two-room apartment Three-room apartment
GENERAL VIEW
GENERAL VIEW
SCHEME OF ENERGY EFFICIENT SOLUTIONS
AIRATIONAPARTAMENTS’ SCHEMES FOR DIFFERENT WEATHER
SECTION A-A
SECTION B-B
AKUSTIC AND INSOLATION SCHEME
AKUSTIC AND INSOLATION SCHEME
MULTI-COMFORT DESIGNER A. PROJECT DATA I. OVERHEATING CALCULATION G. HVAC OBJECT MCH 1 EXTERIOR THERMAL TRANSMITTANCE 1161.30 HEAT RECOVERY SYSTEM: 95.00 CLIMATE ZONE DUBAI GROUND THERMAL TRANCMITTANCE: 26986.31 SUBSOIL HEAT EXCHANGER: 33.00 CONSTRUCTION: NEW VENTILATION TRANSMITTION AMBI… 937.86 BUILDING VENTILATION TRANSMITTION GRO… 0.00 H. SUMMER VENTILATION STRATEGY BUILDING TYPE: RESIDENTIAL SOLAR APERTURE: 141.68 USAGE FOR LIVING SUMMER AIR EXCHANGE RATE (… 0.20 FREQUENCY OF OVERHEATING: 47.82 DESIGN T( ºC) 22 B. AREA INPUT SUMMER AIR EXCHANGE RATE (… 0 WITH HEAT RECOVERY SYSTEM NO SUM OF LIVING AREA: 5280.00 NIGHT VENTILATION: FULLY OPEN WIND +‘(25%) 1h’ SUM OF HEATED SPACE VOLUME: 14210.00 DAY VENTILATION: TITED WINDOWS +‘(25%) 1h' A/V RATIO: 0.37 SUM OF THERMAL ENVELOPE: 3415.80 I. HEAT DEMAND CALCULATIONS C. OPAQUE ELEMENTS TRANSMISSION HEAT LOSSES: 1423.81 ROOF FLAT: 0.11 VENTILATION HEAT LOSSES: 418.94 WALL AGAINST AIR: 0.11 TOTAL HEAT LOSSES: 1842.74 SLAB AGAINST GROUND: 0.10 INTERNAL HEAT GAINS: 1333.56 D. WINDOWS/ DOORS AVAILABLE SOLAR HEAT GAINS: 2553.59 WINDOWS: 0.73 TOTAL HEAT GAINS: 1819.20 DOORS: 0.80 ANNUAL HEAT DEMAND: 23.55 SPECIFIC ANNUAL HEAT DEMAND: 0.00 E. QUALITY AIRTIGHTNESS RATE: 0.60 I. COOLING DEMAND CALCULATIONS THERMAL BRIDGE-FREE: YES Specific Annual Heat NEGATIVE HEAT LOADS: 28705.78 F. SHADING VENTILATION HEAT LOSSES: 26986.31 Demand : 0.00 kWh/a per m2 (STANDART + SUMMER SHADING) TOTAL HEAT LOSSES: 55692.09 315º 0.07 INTERNAL HEAT GAINS: 266.11 Specific Annual Cooling 225º 0.70 AVAILABLE SOLAR HEAT GAINS: 2553.59 135º 0.00 USEFULL HEAT LOSSES: 142.76 Demand : 10 . 52 kWh/a per m2 45º 0.70 USEFULL COOLING DEMAND: 55549.33 HORIZONTALº 0.70 SPECIFIC ANNUAL COOLING DEMAND: 10.52
THANK YOU FOR YOUR ATTENTION
Recommend
More recommend