Circuit Solver TM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS www.CircuitSolver.com Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM The Problem The Solution Install a Circuit Solver


  1. Circuit Solver TM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS www.CircuitSolver.com

  2. Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM The Problem The Solution Install a Circuit Solver™ on each hot water supply branch line immediately downstream of the last runout to a hot tap. 1 Water fmows to the path of least resistance. 2 Many buildings require multiple branches off the hot water supply line. 3 Hot water use is hyper-dynamic, so the path of least resistence constantly changes. 4 Manual fmow control valves cannot effjciently resolve these issues. When entering water temperature is below the Circuit Solver™ setpoint, the thermal actuator will begin to open the valve to establish a fmow rate that will achieve the set point. If the water temperature exceeds the set point by 3°F , the valve will begin to throttle back to fjnd the current equilibrium point. Continuously operating at the optimum temperature minimizes system heat-loss thereby saving energy. This constant, automatic response to water temperature enables each hot water branch to quickly and consistently deliver the right temperature of hot water to each connected fjxture. Design Features • Stainless steel body with NPT female connections • Thermal actuator develops 40 lbs. of thrust to keep valve orifjce free of deposits • Meets ANSI/AWWA C800 • Removable thermal actuator • Stainless valve plug, thermal actuator piston and return spring • Rated for at least 200,000 cycles • Complies with California AB1953 • NSF-61 Compliant PAGE 2 Therm-Omega-Tech, Inc. TEL: 215-674-9992 TOLL FREE: 1-877 -379-8258 FAX: 215-674-8594 WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM 353 IVYLAND ROAD, WARMINSTER, PA 18974-2205

  3. Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM Multi-Branch Hot Water Recirculation Diagram EXP. TMV TANK Z Other advantages of installing the Circuit Solver™ 3 1 2 Eliminates the need to oversize Minimizes heat-loss by Lowers GPM fmow in hot system recirculating pumps to reducing fmuctuations in average water return lines, minimizing create constant fmow through temperature and GPM of the erosion-corrosion problems manually adjusted balancing common return line. caused by excessive velocity. valves. With the Circuit Solver™ Thermal Recirculation Valve you get hot water where you need it at every turn of the tap automatically, reliably and economically PAGE 3 Therm-Omega-Tech, Inc. TEL: 215-674-9992 TOLL FREE: 1-877 -379-8258 FAX: 215-674-8594 WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM 353 IVYLAND ROAD, WARMINSTER, PA 18974-2205

  4. Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM CIRCUIT SOLVER™ APPLICATION GUIDE MUL TI-BRANCH COMESTIC HOT WATER SYSTEM SINGLE CONTINUOUS DOMESTIC HOT WATER SUPPL Y LOOP (NO BRANCHES) Install Circuit Solver™ in the hot water supply line as soon as it becomes a hot water return line (i.e., downstream of the last fjxture served by the hot water supply line). TEMPERED WATER Note: Why use Circuit Solver™ when HOT there are no branch lines? WATER COLD WATER TMV TO CONSERVE ENERGY The Circuit Solver™ will modulate fmow to precisely match system heat-loss. COLD WATER PAGE 4 Therm-Omega-Tech, Inc. TEL: 215-674-9992 TOLL FREE: 1-877 -379-8258 FAX: 215-674-8594 WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM 353 IVYLAND ROAD, WARMINSTER, PA 18974-2205

  5. Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM CIRCUIT SOLVER™ APPLICATION GUIDE BUILDINGS WITH WIDEL Y SPACED RANDOM FIXTURE LOCATIONS Install Circuit Solver™ where hot water supply lines randomly interconnect to automatically assure even temperature distribution. From Water Heater To Water Heater PAGE 5 Therm-Omega-Tech, Inc. TEL: 215-674-9992 TOLL FREE: 1-877 -379-8258 FAX: 215-674-8594 WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM 353 IVYLAND ROAD, WARMINSTER, PA 18974-2205

  6. Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM CIRCUIT SOLVER™ APPLICATION GUIDE CIRCUIT SOLVER™ MODEL NUMBER SELECTION 1 INSTALLATION SCHEMATIC Match the pipe size. OPTIMUM 2 Select the desired return water temperature. ACCEPTABLE For Example 1. Branch hot water line is 3/4” IPS. 2. Return temperature is 110°F 3. Select Model Number CS-3/4-110 COMMENTS AND CAUTIONS Circuit Solver™ will evenly distribute hot water temperature to every fjxture as long as hot water is available. However, that cannot happen if... 3 1 2 There is a cross connection There is signifjcant pressure The recirculation pump is not joining cold water to hot water. differential between the cold and working properly. hot water distribution systems. PAGE 6 Therm-Omega-Tech, Inc. TEL: 215-674-9992 TOLL FREE: 1-877 -379-8258 FAX: 215-674-8594 WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM 353 IVYLAND ROAD, WARMINSTER, PA 18974-2205

  7. Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM 1 5 3 6 OUTLET INLET 4 2 Item Description Material 1 Valve Body 303 SS 2 Valve Plug 303 SS 3 Spring Stainless Steel 4 Thermal Actuator 303 SS 5 Carrier 303 SS 6 All Shaded Area Water Passage Note: The valve plug is shown in the fully open position. As temperature rises, the thermal actuator moves it to the right towards the inlet port to limit fmow to a trickle as temperature exceeds the set point. GPM@1 PSI Δ P Diameter Length Weight Max Pressure Max Temp Model No. Cv NPT In. In. lbs. PSIG °F CS- ½ -XXX 1.2 ½ 1.13 2.75 0.06 200 300 CS- ¾ -XXX 1.7 ¾ 1.38 3.13 0.07 200 300 CS-1-XXX 3.2 1 1.75 3.38 1.60 200 300 CS-1¼-XXX 5.0 1¼ 2.13 4.60 2.70 200 300 CS-1½-XXX 7.5 1½ 2.38 4.60 3.80 200 300 CS-2-XXX 14.0 2 3.00 4.88 5.60 200 300 Model Number Selection XXX refers to the desired return water temperature. Use that temperature to complete the model number. For example, if you want 110°F return water and the Circuit Solver™ is to be installed on a 3/4” line, the model number would be CS-3/4-110. PAGE 7 Therm-Omega-Tech, Inc. TEL: 215-674-9992 TOLL FREE: 1-877 -379-8258 FAX: 215-674-8594 WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM 353 IVYLAND ROAD, WARMINSTER, PA 18974-2205

  8. Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM Resources Circuit Solver Home Page www.CircuitSolver.com Circuit Solver Video youtu.be/8aDFhWAOhDk Download This Brochure http://bit.ly/PgDXi1 Recirculation Pump Guide http://bit.ly/RcFNTC Energy Savings Related to Circuit Solver http://bit.ly/Uzkxdz Visit the Circuit Solver Home Page PAGE 8 Therm-Omega-Tech, Inc. TEL: 215-674-9992 TOLL FREE: 1-877 -379-8258 FAX: 215-674-8594 WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM 353 IVYLAND ROAD, WARMINSTER, PA 18974-2205