SURE-SCOPE PRESENTATION Single-Use One Piece Laryngoscope with Built-In Light Source NEW & IMPROVED RE REV 0108 01082016
Did you know… There are bacteria on 86% of “disinfected” instrument handles in in hospitals! A recent study 1 revealed bacteria on 86% of instrument handles. These handles were disinfected and designated ‘ready for use’ in hospital settings. This study demonstrates a clear potential for transmission of pathogens, and highlights a clear risk to both staff and patients. 1 D. Williams, J. Dingley, C. Jones, N. Berry. ‘Contamination of laryngoscope handles’ Journal of hospital infection (2010) 74, 123-128 There are re 4.5 .5 hospital in infe fections fo for r every 100 patient admissions and nearly 100,000 deaths annually. (source: CDC) There are re approximately 1.7 .7 mil illi lion hospital-acquired in infe fections in in U.S .S. hospitals, costing over $5 bil illio ion annuall lly. . (source: CDC)
SURE-SCOPE Sin ingle-Use One Pie iece Laryngoscope NEW & IMPROVED
New SURE-SCOPE Features Wider handle with added grip On/off switch now available on MIL ILLER 2 and MIL ILLER 3 (avail ilable le on all ll adult lt models in in 2016) Shorter/tapered LED housing on MIL ILLER 2 2 and and MIL ILLER 3 3 (avail ilable le on all ll adult lt models in in 2016) MIL ILLER 00 now available
Top 5 Benefit its of SURE-SCOPE Reduce Risk of Cross-Contamination Revolutionary One Piece Design Built-In Targeted Light Source Cost Per Intubation Entirely Single-Use
Reduce Ris isk of Cross-Contaminatio ion Problem: A 2009 study published in Anesthesia & Analgesia found 75 percent of laryngoscope handles they tested were positive for bacteria. Even following mandates for cleaning and disinfecting leaves pathogens that can transfer from one patient to the next. Solution: SURE-SCOPE eliminates the time and expense of reprocessing, reducing the risk of cross-contamination by obsoleting stainless steel devices, reusable light sources, handles, and blades.
Revolutionary ry One Pie iece Desig ign Problem: Most laryngoscope systems require assembly and testing prior to each use. Attachment of a disposable blade and verification of the light source is necessary before every intubation. Reusable handles are exposed to rigorous disinfection and harsh chemicals which compromises the integrity of the blade and light source over time. Solution: SURE-SCOPE single-use one piece laryngoscope maintains blade integrity. No assembly and no additional parts required. In addition, there is no risk of corrosion at the electrical contact point to reduce the efficiency of the light source.
Buil ilt-In Targeted Lig ight Source Problem: Most laryngoscope light sources burn through batteries or constantly need charging. They can be difficult to focus, making intubations harder. The cleaning and disinfecting process corrodes the electrical contact points causing the light to flicker or fail during intubation. Solution: Never worry about light source failure again. Each SURE-SCOPE comes with a built-in ultra bright LED light source located at the distal tip of the laryngoscope blade. The SURE-SCOPE light source does not utilize a light pipe so the maximum power of the light source is fully realized. High-powered illumination is achieved without generating any damaging heat.
Cost t Per In Intu tubatio ion Problem: According to a study conducted by Southeast Health, reusable laryngoscopes can cost as much as $27.40 per intubation. Reusable devices require the facility to stock handles and/or blades. Add to that the cost of reprocessing, the units, and powering the light source. Solution: The one piece design of SURE-SCOPE eliminates the need for additional parts and components like disposable blades or replacement parts/components. SURE-SCOPE is entirely single-use; the facility incurs no additional reprocessing expenses. Medical facilities can cut their cost per intubation to under $10.
Enti tirely Sin ingle le-Use Problem: Reusable parts and components create unnecessary liability. They elevate the risk of cross-contamination and are more likely to fail due to wear and tear. In addition, reusable parts and components add cost. They need to be reprocessed after each use and replaced when broken or misplaced. Solution: SURE-SCOPE is an entirely single-use device; the facility incurs NO NO additional expenses.
Il Illumination Strength Study OBP Medical conducted a study comparing the illumination strength of three single-use laryngoscope systems: OBP Medical’s SURE-SCOPE, Competitor A, and Competitor B. Of the three models, OBP Medical’s SURE-SCOPE offers the brightest light source. The weak illumination strength demonstrated during this study makes both Competitor A’s and B’s product ineffective choices. Of the three products, SURE-SCOPE is is cle learly the best choice. The results from OBP Medical’s study are lis listed on the foll llowing slid lide.
Il Illumination Strength Study Results OBP Medical’s SURE -SCOPE: 10,000 LUX Light source powered by three alkaline button batteries. These batteries are low voltage and toxic materials per federal E.P.A. guidelines. No light pipe and optimal positioning of the light source ensure the full potential of the illumination strength is realized. Competitor A: : 2,6 ,600 – 3,0 ,000 LUX Light source powered by two AA batteries (sold separately). These batteries contain over 30 times the waste of the batteries used in SURE-SCOPE. Competitor B: : 1,6 ,600 – 2,6 ,600 LUX Broad spread due to the light pipe connection. Light source powered by two LR1 batteries. These batteries contain over 12 times the waste of the batteries used in SURE-SCOPE.
Patient Safety Patient safety is is a primary concern. • SURE-SCOPE help lps to to: Maximize infection control Maximize cleanliness Maximize efficiency Eliminate the risk of cross-contamination Eliminate the need to monitor sterilization procedures and tracking
Revolutionary Material Each SURE-SCOPE is made of a reinforced nylon polyarylamide compound, offering exceptional strength and rigidity never before seen in a single-use laryngoscope. Each SURE-SCOPE blade is validated to support over 40lbs of blade force, 4 ti times hig igher th than standard in intu tubation requirements*. *The Association of Anaesthetists of Great Britain and Ireland concluded that approximately 10lbs of force is needed to intubate the average patient.
Conclusion With the rising cost of healthcare in the spotlight, medical facilities need to utilize the most cost-effective and practical tools available. SURE-SCOPE offers savings and construction that is more efficient and eliminates cross-contamination issues found with laryngoscopes that require reusable parts and components. Add a targeted light source that improves visualization and an ergonomic design for user comfort; it is clear why SURE-SCOPE is the right choice for your healthcare facility.
SURE-SCOPE Batt tteries The SURE-SCOPE lig light source co contains modern alk lkali line batteries. Alkaline batteries do not contain toxic materials per federal E.P.A. guidelines. “Button” style AG3 batteries contain only enough chemistry for a single use. It would take 300 AG3 batteries to equal the chemistry volume of just 1 average alkaline flashlight battery. * For additional battery related information please visit https://obpmedical.com/company/disposable-medical-device-batteryinformation/ * Check EPA guidelines for battery disposal in your state.
SURE-SCOPE Product In Information • Siz izes: SURE-SCOPE is available in 8 blade sizes: MAC 2 (Item # C090120) MAC 3 (Item # C090130) MAC 4 (Item # C090140) MILLER 00 (Item # C090205) MILLER 0 (Item # C090200) MILLER 1 (Item # C090210) MILLER 2 (Item # C090220) MILLER 3 (Item # C090230) • All ll SURE-SCOPE are la latex fr free • All ll SURE-SCOPE co come pack cked sterile le • Medassets co contract ct # MS02268 For additional information please visit www.obpmed edical.com or call 1-978 978-291-6853.
SURE-SCOPE Testimonials “Our physic icia ians li like th that SU SURE- SCOPE is plastic so they don’t have to worry about hitt ittin ing te teeth th and th the li light is is by fa far r so some of f th the brig rightest th they have work rked with ith .” Chad Anderson Purchasing/Materials Management Crosstown Surgery Center “ I I use sed SU SURE-SCOPE today to in intubate a morb rbid idly ly obese patie ient with ith a sh short neck. . It It was s gre reat – li light was much bett tter th than our r meta tal l handle les and meta tal l bla lades; li light st stayed brig right fo for r ove ver r 20 minu inutes. St Stro rong pla lastic ic .” Gabe Wilson M.D. Medical Director, ED CHRISTUS Santa Rosa Hospital 18
Recommend
More recommend