Approved Sound Proofed Systems Building owners, consultants and contractors who want to know if the considered Soundproof System fulfill the requirements of the DIN4109 should ask the piping system supplier for the official Test Report and


  1. Approved Sound Proofed Systems Building owners, consultants and contractors who want to know if the considered Soundproof System fulfill the requirements of the DIN4109 should ask the piping system supplier for the official Test Report and compare to others. Only systems which has Values in the comparison are from this room been carried out under the UG rear Which is the relevant room same conditions (  same according DIN4109 laboratory) can be compared.

  2. Comparison Sound Proofed Systems In the following chard we will show you the values measured in the German FRAUNHOFER INSTITUT FÜR BAUPHYSIK conforming the test report P-BA 265/2007e for our SOUNDPROOF PLUS system respectively conforming test report P-BA 288/2007e for our SOUNDPROOF system.

  3. Comparison Sound Proofed Systems All systems has been carried out under the same conditions in the German FRAUNHOFER INSTITUT FÜR BAUPHYSIK 30 dBA TERRAIN PLUS+ TERRAIN ECO 25 REHAUPIANO-Plus WAVIN AS 20 URALITA AR-M1 AQUA SILENT (3-layer) 15 FRIAPHON (3-layer) MUTE Ferroplast 10 Geberit SILENT dB20 PHONOFIRE (3-layer) 5 Blue Power (3-layer) Düker (cast iron) 0 0,5 l/s 1,0 l/s 2,0 l/s 4,0 l/s Values in dBA measured in room “UG -rear ” with two clamps (all this information is taken from the manufacturers Website at that moment)

  4. Reaction to fire Performance EUROCLASS / Norm UNE EN 13501-1:2002 Near all member countries of the European Union (EU) have adopted the harmonized Euroclass system of reaction to fire performance of building products The fire performance of the PVC-U from TERRAIN SDP regarding the above mentioned norm is as following: B / S1 / D0 A1, A2, B, C, D, F = Classification regarding the FIRE PROPOGATION S1, S2, S3 = Classification regarding the SMOKE PRODUCTION D0, D1, D2 = Classification regarding the DROPS / PARTICLES

  5. Assignment of the EuroClasses to the usual building material classes according DIN4102-1 Additional requirements Building material Building-Authority European Class class according No production of description according EN 13501-1 No smoke DIN4102 flaming droplets A1 A1 x x Non-Combustible A2 - s1 d0 A2 B - s1 d0 TERRAIN SDP x x C - s1 d0 A2 - s2 d0 A2 - s3 d0 B - s2 d0 x B - s3 d0 C - s2 d0 B1 C - s3 d0 Low flammability A2 - s1 d1 As it can be seen, the DIN4102 A2 - s1 d2 don’t differentiate much the B - s1 d1 x materials. However, SDP has B - s1 d2 the best result that can be C - s1 d1 achieve for burning materials! C - s1 d2 A2 - s3 d2 B - s3 d2 C - s3 d2 D - s1 d0 D - s2 d0 x D - s3 d0 E B2 Normal flammability D - s1 d2 D - s2 d2 D - s3 d2 E – d2 F B3 Easily inflammable

  6. Reaction to fire Performance EUROCLASS / Norm UNE EN 13501-1:2002

  7. Reaction to fire Performance EUROCLASS / Norm UNE EN 13501-1:2002 The new European Euro classes “Fire Protection Classification” EUROCLASS Time to “flash over” acc. the “Room Corner Test” No “flash over”; Calorific Value < 2 MJ/Kg A1 No “flash over”; Calorific Value < 3 MJ/Kg A2 No “flash over” TERRAIN SDP B C 10 to 20 minutes Remarks: PVC isn’t a polyolefin and therefore it D 2 to 10 minutes hasn’t “flash over” effect which is very important to protect against fire. E 0 to 2 minutes PE, PP, etc. are polyolefin's and therefore they burn much more. Not defined F

  8. Especial items to protect against fire We offer especial Firewall Sleeve protects the smock and fire propagation to the upper floors or other rooms to be protected .

  9. The following points are important when considering a Soundproof Conclusion System: The system must be installed as a “system” and according the manufacturers guidelines. The system shall be tested in the German Fraunhofer Institute. Only in this way the Owner or Consultant can be sure about its performance. The consultant or contractor shall compare the performance of the systems requiring the official test report from the Fraunhofer Institute. If required, additional insulation actions has to be done to achieve the required noise levels. Choose a system with best fire classification

  10. Reasons to use TERRAIN SDP • Best values regarding sound reduction performance • Best fire protection according UNE EN 13501-1 (B-s1-d0) • Easy and fast installation • Many fittings with HIGH-IMPACT Performance • High chemical resistance and durability of PVC-U • Professional solutions regarding the fire protection in stacks using our Fire-Collars (Firewall Sleeve) • Competitive price